Inhibited Admiralty Brass tubes – C44300 – have high corrosion resistance, and primarily used for tubing of steam condensers cooled with fresh, salt, or brackish water. They are also used for heat exchangers in oil refineries, in which the corrosion from sulfur compounds and contaminated water may be very severe. For industrial processes, it is used for feed-water heaters and heat-exchanger equipment.

| Brass Tubing & Pipe - Technical Specification Sheet | ||
| Alloy / UNS Designation | Type & Manufacturing Standard | Standard Sizes (OD & Wall Thickness) |
| C26000 - Cartridge Brass (70/30) | Seamless, Cold Drawn (ASTM B135) | OD: 1/8" - 3" (3.18mm - 76.2mm) Wall: 0.014" - 0.125" (0.36mm - 3.18mm) Thin Wall: 0.014" - 0.028" |
| C36000 - Free-Cutting Brass | Seamless & Welded (ASTM B135, ASTM B587) | OD: 1/4" - 2" (6.35mm - 50.8mm) Wall: 0.028" - 0.083" (0.71mm - 2.11mm) Standard Pipe Sizes: 1/8" - 2" NPS |
| C23000 - Red Brass (85-15) | Seamless (ASTM B135) | OD: 1/4" - 4" (6.35mm - 101.6mm) Wall: 0.028" - 0.125" (0.71mm - 3.18mm) Plumbing Sizes: 1/2" - 4" |
| C44300 / C44400 / C44500 - Admiralty Brass | Seamless (ASTM B111, ASTM B395) | OD: 3/8" - 1.5" (9.53mm - 38.1mm) Wall: 0.028" - 0.065" (0.71mm - 1.65mm) (Standard Condenser Sizes) |
| C46400 / C48500 - Naval Brass | Seamless, Drawn (ASTM B135) | OD: 1/4" - 3" (6.35mm - 76.2mm) Wall: 0.028" - 0.125" (0.71mm - 3.18mm) |
| C68700 - Aluminum Brass (76-22-2-0.04 As) | Seamless (ASTM B111, ASTM B395) | OD: 1/2" - 2" (12.7mm - 50.8mm) Wall: 0.028" - 0.083" (0.71mm - 2.11mm) |
| C27200 / C27400 - Yellow Brass (63-37) | Seamless & Welded (ASTM B135) | OD: 1/8" - 2.5" (3.18mm - 63.5mm) Wall: 0.014" - 0.065" (0.36mm - 1.65mm) Architectural Sizes: 1/2" - 2" OD |
| Standard Manufacturing Parameters & Supply Details | ||
| Lengths Available: | ||
| Length Type | Standard Lengths | Tolerance |
| Straight Lengths (Imperial) | 12 ft (3.66m), 20 ft (6.10m) | ±1/8" |
| Straight Lengths (Metric) | 3m, 4m, 6m | ±3mm |
| Precision Cut | 1" - 240" (25mm - 6,096mm) | ±0.010" (±0.25mm) |
| Coiled Tubing (Annealed) | Up to 100 ft (30.5m) continuous | N/A |
| Coiled Tubing (Hard Temper) | Up to 50 ft (15.2m) continuous | N/A |
| Tolerances (Per ASTM B135 / ASTM B587): | ||
| Parameter | Standard Tolerance | Precision Tolerance |
| Outside Diameter (up to 1") | ±0.003" (±0.08mm) | ±0.0015" (±0.038mm) |
| Outside Diameter (1" - 2") | ±0.004" (±0.10mm) | ±0.002" (±0.051mm) |
| Outside Diameter (2" - 4") | ±0.005" (±0.13mm) | ±0.003" (±0.076mm) |
| Wall Thickness | ±10% of nominal | ±5% of nominal |
| Concentricity | 90% minimum | 95% minimum |
| Straightness (per 3 ft) | 1/8" (3mm) | 0.030" (0.76mm) |